CertBenchTrade Exam Manual
Pest Control & Ag • PEST-CORERef: National Pesticide Applicator Certification Core Manual (EPA / NASDA)

Pesticide Applicator Core Certification Practice Exam (National & State)

Prepare for your state Commercial or Private Pesticide Applicator Core exam with FIFRA law drills, label & signal word traps, PPE/WPS rules, IPM, and sprayer calibration math.

Passing Threshold
70% (75% in select states)
Official Format
50–100 Qs • State Proctored • Core + Category
Governing Agency
EPA (FIFRA) & State Departments of Agriculture
LOCAL READINESS BENCHMARK • SAVED AUTOMATICALLY (NO LOGIN)
Not Started0 of 30 bank questions drilled • 0/14 hard numbers locked

FIFRA Laws, Labeling & IPM

Federal FIFRA statutes, 'The Label Is The Law', toxicity categories, Danger/Warning/Caution signal words, IPM thresholds, and Restricted-Use Pesticide (RUP) recordkeeping.

DANGER–POISON vs. DANGER vs. WARNING vs. CAUTIONFIFRA Section 3, 24(c) SLN, and Section 18 exemptionsRestricted-Entry Interval (REI) vs. Pre-Harvest Interval (PHI)
Drilled: 0/10Official: 25 Qs • Pass 70%
Drill Laws & Labels

PPE, Toxicology & Environmental Drift

Routes of exposure (dermal absorption rates), LD50 toxicity comparisons, temperature inversions, droplet size vs. spray drift, pollinator protection, and spill response (Three C's).

Lower LD50 = MORE toxic (classic exam trap!)Temperature inversion & droplet size drift controlSpill control: Control, Contain, Clean up
Drilled: 0/10Official: 25 Qs • Pass 70%
Drill Safety & Drift

Formulations & Calibration Math

Boom sprayer GPA calculations, nozzle pressure vs. flow rate (4× pressure to double flow), tank mix percentages, active ingredient (AI) math, and dry/liquid formulations.

GPA = (GPM × 5,940) ÷ (MPH × W inches)43,560 sq ft = 1 acre • 128 fl oz = 1 gallonQuadruple pressure (4×) to double nozzle output
Drilled: 0/10Official: 20 Qs • Pass 70%
Drill Calibration Math

EPA Acute Toxicity Categories & Required Signal Words

Tested on every single state Pesticide Core exam.

CategorySignal WordOral LD₅₀ (mg/kg)Estimated Fatal Oral Dose (Adult)
Category I (Highly Toxic)DANGER — POISON (Skull)0 – 50A few drops to 1 teaspoon
Category I (Corrosive)DANGER (No Skull)Severe eye/skin injuryIrreversible corneal/skin burn
Category II (Moderately Toxic)WARNING50 – 5001 teaspoon to 1 ounce
Category III (Slightly Toxic)CAUTION500 – 5,0001 ounce to 1 pint
Category IV (Relatively Non-Toxic)CAUTION (or none)> 5,000Greater than 1 pint
Source: 40 CFR § 156.62–64 & EPA National Core Manual.

State Licensing Rules & Exam Requirements

Frequently Asked Questions — Pesticide Core

Is the Pesticide Applicator Core exam the same in every state?

The core scientific and federal concepts—FIFRA law, label reading, signal words, PPE, LD50 toxicology, drift, and calibration math—come from the EPA National Core Manual and overlap ~80% across all 50 states. Each state adds its own agency rules, recordkeeping periods, and local notification laws.

Can I use a calculator on the Pesticide Core exam?

Yes—almost all state testing centers provide a basic non-programmable calculator (or on-screen calculator), though smartphones are strictly prohibited. You must know the 43,560 sq ft/acre constant, 128 fl oz/gal, and the GPA calibration formula by heart.

What score do I need to pass the Pesticide Applicator Core exam?

The vast majority of U.S. states (including TX, CA, FL, NY, OH, PA, IL, GA, NC, MI, VA, and IN) require a minimum score of 70% on both the Core exam and each Category exam.

Who Needs This License?

Commercial pest control techs, lawn care/turf applicators, turfgrass managers, agricultural sprayers, and landscape pros applying Restricted-Use Pesticides (RUPs).